Areas of Usage: These cables are designed to provide communication between devices can be used in many areas from control engineering to security systems.
CABLE CONSTRUCTION | |||||
PRODUCT CODE | CORE NUMBERS x SECTION | STRANDED COPPER CONDUCTER (Cu) |
INSULATION MATERIAL AND DIAMETER(mm ±0,05) | OUTER SHEATH AND DIAMETER (±0,10) |
WEIGHT (WITHOUT REEL) |
2x1,00mm² | 32x0,19 mm | PVC 2,5 | PVC5.70 | 54 | |
3x1,00mm² | 32x0,19 mm | PVC 2,5 | PVC 6,10 | 61 | |
4x1,00mm² | 32x0,19 mm | PVC 2,5 | PVC 6,70 | 76 | |
5x1,00mm² | 32x0,19 mm | PVC 2,5 | PVC 7,20 | 93 | |
6x1,00mm² | 32x0,19 mm | PVC 2,5 | PVC 8,10 | 114 | |
8x1,00mm² | 32x0,19 mm | PVC 2,5 | PVC 8,60 | 139 | |
10x1,00mm² | 32x0,19 mm | PVC 2,5 | PVC10.40 | 179 | |
12x1,00mm² | 32x0,19 mm | PVC 2,5 | PVC10.90 | 199 |
TECHNICAL AND ELECTRICAL DATA | ||||
PRODUCT CODE | CONDUCTOR RESISTANCE | INSULATION RESISTANCE | OPERATING VOLTAGE | CAPACITANCE (pF/m) |
< 20Ω/km. | < 200MΩ x km. | 300/500V | 120pF/m | |
< 20Ω/km. | < 200MΩ x km. | 300/500V | 120pF/m | |
< 20Ω/km. | < 200MΩ x km. | 300/500V | 120pF/m | |
< 20Ω/km. | < 200MΩ x km. | 300/500V | 120pF/m | |
< 20Ω/km. | < 200MΩ x km. | 300/500V | 120pF/m | |
< 20Ω/km. | < 200MΩ x km. | 300/500V | 120pF/m | |
< 20Ω/km. | < 200MΩ x km. | 300/500V | 120pF/m | |
< 20Ω/km. | < 200MΩ x km. | 300/500V | 120pF/m |
MECHANICAL DATA | ||
PRODUCT CODE | WORKING TEMPERATURE | BENDING RADIUS |
-30-70°C | 8x outer diameter | |
-30-70°C | 8x outer diameter | |
-30-70°C | 8x outer diameter | |
-30-70°C | 8x outer diameter | |
-30-70°C | 8x outer diameter | |
-30-70°C | 8x outer diameter | |
-30-70°C | 8x outer diameter | |
-30-70°C | 8x outer diameter |
PACKAGE: 100m Plastic Reel/500m Wooden Reel (It change change depends on customer request)
OUTER SHEAT COLORS: BLACK, BLUE, RED, YELLOW, GREEN