Areas of Usage: These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles.
CABLE CONSTRUCTION | |||||
PRODUCT CODE | CROSS SECTION (Cu) | STRANDED COPPER CONDUCTER (Cu) |
INSULATION MATERIAL AND DIAMETER(mm ±0,03) | WALL THICKNESS min (mm) |
APPROXIMATE WEIGHT (kg/km) |
FA035 | 0,35 mm² | 7x0,26 mm | PVC (according to ISO 6722-1, CLASS B and CLASS C) 1,3 |
0,20 | 5,00 |
FA050 | 0,50 mm² | 19x0,19 mm | PVC (according to ISO 6722-1, CLASS B and CLASS C) 1,6 |
0,22 | 7,00 |
FA075 | 0,75 mm² | 19x0,23 mm | PVC (according to ISO 6722-1, CLASS B and CLASS C) 1,9 |
0,24 | 9,00 |
FA100 | 1,00 mm² | 19x0,26 mm | PVC (according to ISO 6722-1, CLASS B and CLASS C) 2,4 |
0,24 | 11,00 |
FA150 | 1,50 mm² | 19x0,32 mm | PVC (according to ISO 6722-1, CLASS B and CLASS C) 2,4 |
0,24 | 16,00 |
FA200 | 2,00 mm² | 19x0,38 mm | PVC (according to ISO 6722-1, CLASS B and CLASS C) 2,8 |
0,28 | 22,00 |
FA250 | 2,50 mm² | 19x0,41, mm | PVC (according to ISO 6722-1, CLASS B and CLASS C) 3,0 |
0,28 | 26,00 |
TECHNICAL AND ELECTRICAL DATA | |
PRODUCT CODE | CONDUCTOR RESISTANCE |
FA035 | <54,4 Ω/km |
FA050 | <37,1 Ω/km |
FA075 | <24,7 Ω/km |
FA100 | <18,1 Ω/km |
FA150 | <12,7 Ω/km |
FA200 | <9,42 Ω/km |
FA250 | <7,6 Ω/km |
MECHANICAL DATA | |
PRODUCT CODE | ÇALIŞMA SICAKLIĞI |
FA035 | -40 to +105°C (CLASS B) -40 to +125°C (CLASS C) |
FA050 | -40 to +105°C (CLASS B) -40 to +125°C (CLASS C) |
FA075 | -40 to +105°C (CLASS B) -40 to +125°C (CLASS C) |
FA100 | -40 to +105°C (CLASS B) -40 to +125°C (CLASS C) |
FA150 | -40 to +105°C (CLASS B) -40 to +125°C (CLASS C) |
FA200 | -40 to +105°C (CLASS B) -40 to +125°C (CLASS C) |
FA250 | -40 to +105°C (CLASS B) -40 to +125°C (CLASS C) |
PACKAGE: CONIC PACK OR CARTON PACKING (It change change depends on customer request)
OUTER SHEAT COLORS: BLACK, BLUE, RED, YELLOW, GREEN